[Validate](https://www.calibra-genomics.com/#validate) [Monitor](https://www.calibra-genomics.com/#monitor) [Connect](https://www.calibra-genomics.com/#connect) [How it works](https://www.calibra-genomics.com/#how) [FAQ](https://www.calibra-genomics.com/#faq) [Sign up](https://app.calibra-genomics.com)

Validate germline NGS tests for CAP, ISO 15189 and IVDR Art. 5(5)

# Validate with ease. Monitor every run. Stay audit-ready.

Calibra Validate takes each germline NGS test your laboratory develops from its components to an approved validation plan, in your framework's own terms: claims and acceptance criteria, a study schedule worked out for you, accuracy computed with citable tools, and a plan document an auditor can read. Calibra Monitor then follows every run, and tells you when a change calls for revalidation.

[Sign up](https://app.calibra-genomics.com) [See how validation works](https://www.calibra-genomics.com#validate)

Free trial once your account is approved, with a Demo Laboratory of sample data to try every module.

Validation plan · Clinical exome

Every claim checked against the schedule

- Accuracy against the GIAB truth set HG001, HG002
- Repeatability 3 replicates, one run
- Between-day reproducibility 3 prep days
- Between-sequencer reproducibility 2 sequencers
- Capture reaction effect hybrid capture
- Limit of detection not chosen

1. Draft
2. Submitted
3. Approved

Example plan with illustrative values

Scope

## Built for NGS. Germline tests first.

- ### Next-generation sequencing only
  
  Calibra is made for NGS laboratories and NGS-based tests.
- ### Germline laboratory-developed tests today
  
  Claims, criteria and accuracy against the GIAB truth sets cover germline SNVs and small insertions and deletions.
- ### Somatic tests later
  
  Planned, not scheduled yet.

Sequencing platforms supportedShort- and long-read

- Illumina
- MGI
- GeneMind
- Salus
- Oxford Nanopore
- PacBio

Calibra Validate

## From the parts of a test to the evidence that it works.

CAP, ISO 15189 and IVDR Art. 5(5) all ask the same of a laboratory-developed test: say what it claims, test each claim against set criteria, and keep the record. Calibra Validate follows that order of work, and each step reads what the one before it recorded. It is built today for germline laboratory-developed tests.

1. ### Component Library
   
   Everything your tests are built from: reference materials, kits, library preps, barcode kits, robots, sequencers and analysis software, with the details the rest relies on.
   
     - Import from Calibra's curated Global Component Library, or create your own
     - Sequencers arrive from your Data Agents
2. ### Workflows and their configuration
   
   One workflow per test, configured in six guided steps from sample preparation to routine use, as it really runs.
   
     - Robot units, library prep, capture, barcodes, how each sequencer is loaded
     - Sequencing needed per library worked out for you
     - Batch sizes, specimen types and the routine control
3. ### Validation plans
   
   Claims follow from the configuration; each claim carries its acceptance criteria, as editable starting points.
   
     - Accuracy, repeatability and reproducibility between days, sequencers and robots; capture effect; limit of detection
     - Comparison rules that start at best practice and mark every departure
     - Standard limitations stated for you
4. ### Validation Run Planner
   
   Turns the plan into a laboratory schedule: the fewest libraries and runs that prove every claim.
   
     - Finds the cheapest calendar for your sequencers
     - Explains every check in plain words, with fixes when one fails
     - Run sheet with barcode wells, also as CSV
5. ### Datasets and accuracy
   
   Upload the VCFs of your reference materials and compare them with the GIAB truth sets in the app.
   
     - Every VCF format-checked on upload
     - Sensitivity and precision per variant type, with 95 % intervals
     - Pooled per reference material, judged against the plan's criteria
6. ### Review, approval and studies
   
   Submit, approve by a second validation approver, then carry the plan out in a study and record the decision.
   
     - Submitting freezes the workflow configuration with the plan
     - Plan versions, never overwritten
     - A passed study sets the workflow to validated

Validation Run Planner

## The study design, worked out before the first library.

Tell Calibra which reference materials, replicates and prep days you want, and which days your sequencers are free. The planner finds the smallest set of libraries and runs that supports every claim, and shows which claims pass and why.

Each library gets a name, a prep day, a capture and a barcode well; the run sheet lists it all per run. Change the workflow, and the plan shows exactly what changed before it can be submitted.

Validation Run Planner

**Day 1Day 2Day 3** **HG001***Repeat.Reprod.Reprod.* **HG002***Repeat.Reprod.Reprod.* **HG003***AccuracyAccuracy* **HG004***AccuracyAccuracy*

Illustrative plan

Accuracy you can cite

## Published tools, not private statistics.

Variant calls are compared with the GIAB truth sets using RTG vcfeval and bcftools, on hg19 (GRCh37) or hg38 (GRCh38), inside your library prep's target. Each result keeps the tool versions, input checksums and commands, so you can cite the method and the version.

Datasets of one reference material are pooled and judged against the plan's criteria; a dataset worse than the others beyond chance is flagged before you rely on the result. Every step was checked against test data with known answers.

Evaluate per reference · HG002 · 3 datasets pooled

|  | SNV | Indel |
| --- | --- | --- |
| Sensitivity (PPA) | 99.6 % | 97.8 % |
| Precision (PPV) | 99.7 % | 98.1 % |
| 95 % lower bound | 99.5 % | 97.1 % |
| Plan's criterion | ≥ 99 % · met | ≥ 95 % · met |

Illustrative values

The validation plan document

## A plan an auditor can read, in the sections they expect.

Export any plan as a PDF in 18 sections, following the CDC/APHL NGS method validation plan template and a CAP exome verification protocol: purpose and scope, the test system step by step, the study design, acceptance criteria, comparison with the truth set, limitations, approval and revision history, with the run sheet as an annex.

What Calibra does not hold is printed as a gap to complete in your own documents, never filled in for you. Drafts carry a watermark until a second validation approver approves them.

VP-12-v2 · Clinical exome

DRAFT

1. **1**Purpose claims, intended use
2. **6**Test system process, frozen configuration
3. **8**Study design from the planner
4. **9**Acceptance criteria per claim
5. **10**Comparison with the truth set comparison rules
6. **12***Confirmation of findings: not recorded in Calibra*
7. **15**Limitations standard and your own
8. **A**Run sheet annex

Illustrative outline

CAP or IVDR

## In your laboratory's own words.

Choose your laboratory's framework once. Pages, the plan document, the logbook and the audit trail then use its terms.

|  | CAP | IVDR |
| --- | --- | --- |
| The plan | Validation plan | Performance evaluation plan |
| The study | Validation study | Performance study |
| The test | Laboratory-developed test (LDT) | In-house device (Art. 5(5)) |
| Sensitivity | Sensitivity (PPA) | Positive agreement (sensitivity) |

Calibra Monitor

## Once validated, watch every run.

A Data Agent next to the sequencer output sends each lane's QC as the run finishes. Calibra charts it per sequencer, flow cell and lane, with a rolling trend, so you see drift before a threshold fails.

Alert rules watch the metrics and the Data Agents themselves, and reach the people you choose by email or Slack. A QC reviewer closes every alert with a recorded outcome: your nonconforming-work record, written as the work happens.

7580859095 Q30 (%) Logbook: major change Alert rule: Q30 below 80 Lanes over 90 days Rolling median, last 10 runs

Example chart with illustrative data

- Runs → workflows
  
  ### Each run belongs to a workflow
  
  A sequencer's new runs go to its default workflow, so QC is read per test, and a study records the sequencing runs it used.
- Logbook → QC charts
  
  ### Every change on the chart
  
  New reagent lots, maintenance, repairs and software versions go into the workflow's logbook, and appear as markers on the QC charts next to the lanes they may have affected.
- Major change → revalidation
  
  ### Validated, until it is not
  
  A major change sets the workflow to "Revalidation required" until a new study passes; minor ones wait for a QC reviewer to verify them.

Calibra Connect · supplementary

## Read from your analysis platform. Change nothing.

Connect leading NGS analysis platforms with your own API key and pull their workflows, assays and analyses by ID. An assay can become a library prep in your Component Library, and a platform's analysis workflow the last step of your workflow configuration. Connections are read only, always.

**Leading NGS analysis platforms**WorkflowsAssaysAnalyses

Read only

**Calibra**Pulled by IDNothing written back

How it works

## Start with the test you need to validate.

1. ### Sign up
   
   With your work email. Once your account is approved, your laboratory starts a free trial, and your own Demo Laboratory lets you try every module with sample data.
2. ### Describe the test
   
   Add its components and configure its workflow as you run it, from sample preparation to routine use.
3. ### Plan and validate
   
   Set claims and criteria, let the planner lay out the runs, compare your datasets with the truth sets, and take the plan through approval.
4. ### Monitor every run
   
   Install a Data Agent where sequencer output is stored. QC arrives lane by lane; changes go into the logbook.

What Calibra is, and is not

## A record tool. Never a device in the result path.

Calibra records validation evidence and QC decisions for CAP, ISO 15189 and IVDR Art. 5(5). Its wording follows your laboratory's framework.

- ### Patient results stay yours
  
  It never blocks or releases a patient result.
- ### No patient identities
  
  Sample names are hashed by the Data Agent; datasets hold reference materials only.
- ### Platforms are read only
  
  Calibra Connect never changes anything on an analysis platform.
- ### Everything is audited
  
  Every change, data export and download is written to the audit trail.

Questions

## What laboratories ask first.

How are validation numbers computed?

With published, citable tools rather than private statistics code: RTG vcfeval and bcftools against GIAB truth sets, checked on test data with known answers. Accuracy runs today on uploaded datasets; agreement between replicates and results computed inside validation studies come next.

Does it follow CAP or the IVDR?

Either. Each laboratory chooses CAP or IVDR Art. 5(5), and Calibra uses that framework's terms throughout: validation plans or performance evaluation plans, validation studies or performance studies.

Can we try it first?

Yes. Sign up with your work email; once your account is approved, your laboratory starts a free trial, and you get your own Demo Laboratory with sample data in every module.

Which sequencers does it work with?

Calibra Validate works with variant calls (VCF) from any NGS platform, short- or long-read: Illumina, MGI, GeneMind, Salus, Oxford Nanopore, PacBio and others. Calibra Monitor reads QC from MGI sequencers today, and the other major platforms are being added.

Does it support somatic tests?

Not yet. Calibra is built for germline laboratory-developed tests today. Somatic tests are planned, but not scheduled yet.

What leaves our network?

QC numbers. The Data Agent never sends reads (FASTQ), and it hashes sample names before sending.

Is Calibra certified to ISO/IEC 27001?

Not yet. We are working towards readiness and track our status against every requirement. Ask us for where it stands today.

Next step

## Bring the test you need to validate.

Tell us which tests and sequencers you run. We will walk you through a validation plan in the Demo Laboratory and answer your questions.

[Send us a message](https://www.calibra-genomics.com/contact?hsLang=en)

![Calibra Genomics](https://www.calibra-genomics.com/hubfs/raw_assets/public/calibra/images/calibra-logo-footer-dark.svg)

Validate with ease. Monitor every run. Stay audit-ready.

[Privacy policy](https://www.calibra-genomics.com/privacy?hsLang=en) [Terms of use](https://www.calibra-genomics.com/terms?hsLang=en) [Contact](https://www.calibra-genomics.com/#contact)

© 2026 Calibra Genomics

```json
{
  "@context" : "https://schema.org",
  "@type" : "Organization",
  "name" : "Calibra Genomics",
  "url" : "https://www.calibra-genomics.com"
}
```